{"id":3418,"date":"2026-05-23T11:16:05","date_gmt":"2026-05-23T15:16:05","guid":{"rendered":"https:\/\/blog.lufamily.ca\/kang\/?p=3418"},"modified":"2026-05-23T11:16:08","modified_gmt":"2026-05-23T15:16:08","slug":"resetting-solaredge-inverters","status":"publish","type":"post","link":"https:\/\/blog.lufamily.ca\/kang\/2026\/05\/23\/resetting-solaredge-inverters\/","title":{"rendered":"Resetting SolarEdge Inverters"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">In a previous <a href=\"https:\/\/blog.lufamily.ca\/kang\/2025\/04\/13\/solaredge-inverter-error-3x9a\/\" data-type=\"post\" data-id=\"3115\">post<\/a>, one of our two SolarEdge inverters encountered an error and one quick fix is to reset the inverters. This year we had a similar issue.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Three days ago, our solar system encountered a grid voltage issue. Our XWPro inverter was in AC PassThru mode causing the SolarEdge inverters to detect the same grid issue. <a href=\"https:\/\/blog.lufamily.ca\/kang\/2021\/09\/21\/residential-solar-project-initiated\/\" data-type=\"post\" data-id=\"1454\">Our solar system<\/a> is AC coupled. With XWPro handling grid-tied net metering, and battery charging and discharging, and SolarEdge for solar energy generation.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"218\" src=\"https:\/\/blog.lufamily.ca\/kang\/wp-content\/uploads\/sites\/3\/2026\/05\/Screenshot-2026-05-23-at-10.22.26-AM-1024x218.png\" alt=\"\" class=\"wp-image-3420\" srcset=\"https:\/\/blog.lufamily.ca\/kang\/wp-content\/uploads\/sites\/3\/2026\/05\/Screenshot-2026-05-23-at-10.22.26-AM-1024x218.png 1024w, https:\/\/blog.lufamily.ca\/kang\/wp-content\/uploads\/sites\/3\/2026\/05\/Screenshot-2026-05-23-at-10.22.26-AM-300x64.png 300w, https:\/\/blog.lufamily.ca\/kang\/wp-content\/uploads\/sites\/3\/2026\/05\/Screenshot-2026-05-23-at-10.22.26-AM-768x164.png 768w, https:\/\/blog.lufamily.ca\/kang\/wp-content\/uploads\/sites\/3\/2026\/05\/Screenshot-2026-05-23-at-10.22.26-AM-1536x327.png 1536w, https:\/\/blog.lufamily.ca\/kang\/wp-content\/uploads\/sites\/3\/2026\/05\/Screenshot-2026-05-23-at-10.22.26-AM-2048x437.png 2048w, https:\/\/blog.lufamily.ca\/kang\/wp-content\/uploads\/sites\/3\/2026\/05\/Screenshot-2026-05-23-at-10.22.26-AM-1200x256.png 1200w\" sizes=\"auto, (max-width: 709px) 85vw, (max-width: 909px) 67vw, (max-width: 1362px) 62vw, 840px\" \/><figcaption class=\"wp-element-caption\">AC Qualification Limit Exceeded<\/figcaption><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">This grid event cause both SolarEdge inverters to go into a &#8220;Grid Profile Limit&#8221; mode where its AC output was limited to around 100W. When I reset both inverters through the main breaker panel, one recovered while the other continue with the limited output behaviour. To fix the second one, I had to perform a hard reset on the inverter. Below are the steps needed.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"541\" src=\"https:\/\/blog.lufamily.ca\/kang\/wp-content\/uploads\/sites\/3\/2026\/05\/IMG_9855-1024x541.jpeg\" alt=\"\" class=\"wp-image-3422\" style=\"aspect-ratio:1.8928688793953337;width:310px;height:auto\" srcset=\"https:\/\/blog.lufamily.ca\/kang\/wp-content\/uploads\/sites\/3\/2026\/05\/IMG_9855-1024x541.jpeg 1024w, https:\/\/blog.lufamily.ca\/kang\/wp-content\/uploads\/sites\/3\/2026\/05\/IMG_9855-300x159.jpeg 300w, https:\/\/blog.lufamily.ca\/kang\/wp-content\/uploads\/sites\/3\/2026\/05\/IMG_9855-768x406.jpeg 768w, https:\/\/blog.lufamily.ca\/kang\/wp-content\/uploads\/sites\/3\/2026\/05\/IMG_9855-1536x812.jpeg 1536w, https:\/\/blog.lufamily.ca\/kang\/wp-content\/uploads\/sites\/3\/2026\/05\/IMG_9855-2048x1083.jpeg 2048w, https:\/\/blog.lufamily.ca\/kang\/wp-content\/uploads\/sites\/3\/2026\/05\/IMG_9855-1200x634.jpeg 1200w\" sizes=\"auto, (max-width: 709px) 85vw, (max-width: 909px) 67vw, (max-width: 1362px) 62vw, 840px\" \/><figcaption class=\"wp-element-caption\">Main Breaker Panel<\/figcaption><\/figure>\n<\/div>\n\n<div class=\"wp-block-image\">\n<figure class=\"alignleft size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"825\" height=\"1024\" src=\"https:\/\/blog.lufamily.ca\/kang\/wp-content\/uploads\/sites\/3\/2026\/05\/Screenshot-2026-05-23-at-10.26.57-AM-825x1024.png\" alt=\"\" class=\"wp-image-3421\" style=\"aspect-ratio:0.805674892596663;width:234px;height:auto\" srcset=\"https:\/\/blog.lufamily.ca\/kang\/wp-content\/uploads\/sites\/3\/2026\/05\/Screenshot-2026-05-23-at-10.26.57-AM-825x1024.png 825w, https:\/\/blog.lufamily.ca\/kang\/wp-content\/uploads\/sites\/3\/2026\/05\/Screenshot-2026-05-23-at-10.26.57-AM-242x300.png 242w, https:\/\/blog.lufamily.ca\/kang\/wp-content\/uploads\/sites\/3\/2026\/05\/Screenshot-2026-05-23-at-10.26.57-AM-768x954.png 768w, https:\/\/blog.lufamily.ca\/kang\/wp-content\/uploads\/sites\/3\/2026\/05\/Screenshot-2026-05-23-at-10.26.57-AM.png 852w\" sizes=\"auto, (max-width: 709px) 85vw, (max-width: 909px) 67vw, (max-width: 984px) 61vw, (max-width: 1362px) 45vw, 600px\" \/><figcaption class=\"wp-element-caption\">SolarEdge Inverter Control Positions<\/figcaption><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">First I had to switch off the inverter at position A, and then turn off the DC disconnect at position B. I then had to switch off the breaker on the main panel.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The important part is to wait 5 to 10 minutes to wait for the inverter to discharge for the full reset to happen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Once the time has passed, perform the action in reverse. Turn back on the breaker, the DC disconnect (B), and then finally turn back on the inverter (A).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Luckily after this hard reset procedure, the second SolarEdge inverter has been fully restored with normal operation.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>In a previous post, one of our two SolarEdge inverters encountered an error and one quick fix is to reset the inverters. This year we had a similar issue. Three days ago, our solar system encountered a grid voltage issue. Our XWPro inverter was in AC PassThru mode causing the SolarEdge inverters to detect the &hellip; <a href=\"https:\/\/blog.lufamily.ca\/kang\/2026\/05\/23\/resetting-solaredge-inverters\/\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;Resetting SolarEdge Inverters&#8221;<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[122,111,1],"tags":[206,15,28],"class_list":["post-3418","post","type-post","status-publish","format-standard","hentry","category-solar","category-tech","category-uncategorized","tag-solar","tag-solar-system","tag-technology"],"jetpack_featured_media_url":"","jetpack_shortlink":"https:\/\/wp.me\/p7V6i8-T8","jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/blog.lufamily.ca\/kang\/wp-json\/wp\/v2\/posts\/3418","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.lufamily.ca\/kang\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.lufamily.ca\/kang\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.lufamily.ca\/kang\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.lufamily.ca\/kang\/wp-json\/wp\/v2\/comments?post=3418"}],"version-history":[{"count":4,"href":"https:\/\/blog.lufamily.ca\/kang\/wp-json\/wp\/v2\/posts\/3418\/revisions"}],"predecessor-version":[{"id":3426,"href":"https:\/\/blog.lufamily.ca\/kang\/wp-json\/wp\/v2\/posts\/3418\/revisions\/3426"}],"wp:attachment":[{"href":"https:\/\/blog.lufamily.ca\/kang\/wp-json\/wp\/v2\/media?parent=3418"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.lufamily.ca\/kang\/wp-json\/wp\/v2\/categories?post=3418"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.lufamily.ca\/kang\/wp-json\/wp\/v2\/tags?post=3418"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}